+49 (089) 18 93 668 0 - Info@ScienceServices.de   We are here for you! Call us or request a call back here.
Language

Fluoro-Gel with DABCO™, Mounting Medium

Fluoro-Gel with anti-fading agent DABCO™ (1, 4-Diazobicyclo-[2,2,2-octane]) is an aqueous mounting medium for preserving fluorescence of tissues and cell smears. Suitable for FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Cy dyes, Tetramethylrhodamine, Redox.
Grouped product items
Product Name Qty
Fluoro-Gel with DABCO™, 20ml

E17985-01

€208.60 €248.23
Fluoro-Gel with DABCO™, 100ml

E17985-02

€571.90 €680.56
Fluoro-Gel with DABCO™, 250ml

E17985-03

€853.50 €1,015.67
Fluoro-Gel with DABCO™, 1000ml

E17985-04

€1,967.40 €2,341.21

Product Details

Description

Fluoro-Gel with anti-fading agent 1,4-Diazobicyclo-(2,2,2-octane (DABCO™) is an aqueous mounting medium for preserving fluorescence of tissues and cell smears. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Cy dyes, Tetramethylrhodamine and Redox. The fluorescence is retained during prolonged storage at 4°C in the dark.

Instruction for use

  1. Bring the vial to room temperature.
  2. Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light.
  3. Turn the vial upside down and open the dropper to remove any air bubbles.
  4. Apply 3-4 drops of mounting medium directly on top of the specimen and spread out evenly by tilting slide back and forth or spread evenly with a 0.2 ml plastic pipette tip making sure the tissue is not touched.
  5. Excess medium can be removed by touching the edges of slide against paper towel.
  6. Let stand at room temperature for about 5 minutes.
  7. Apply cover slip carefully avoiding air bubbles.
    The specimen is ready for visualization under a microscope.
  8. One can seal the edges of cover slip with nail polish, any organic medium or our Limonene mounting medium (cat. # 17987-01). If a coverslip is not sealed air bubbles will appear in few days.
  9. For storage it is recommended that the slide be stored in the dark at 2-8°C.


Removal of coverslip:
Coverslip can be removed before sealing the edges. Soak slide in warm (37°C) distilled or deionized water for several minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

More Information

More Information
Mandatory sign
Tightly sealed goggles Tightly sealed goggles
M05_Sicherheitsschuhe M05_Sicherheitsschuhe
Symbol GHS
GHS05 GHS05
GHS07 GHS07
Packing Unit 50ml, 150ml, 200ml, 1000ml
Storage Temperature 2-8°C, protect from light, do not freeze
suitable dyes FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Cy dyes, Tetramethylrhodamine, Redox
Suitable for Immunofluorescence, confocal microscopy
Used for Fluorescence
yes
SDS (multilingual) E17985-01/-02/-03/-04