Fluoro-Gel III with PI, Mounting Medium
Product Details
Description
Fluoro-Gel III Mounting Medium is similar to Fluoro-Gel, however, Fluoro-Gel III with the addition of PI (Propidium Iodide) which is a counterstain for DNA, makes this a unique mounting medium, which prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluoro 488, Alexa Fluoro 594, Green Fluorescent protein (GFP), Tetramethylrhodamine, Redox, Phycoerythrin (RP-E), Phyocyanin (PC), and Allophycocyanin (APC). The fluorescence is retained during prolonged storage at 4°C in the dark. This medium does not contain Phenylenediamine, which destroys immunofluorescence of Cy dyes, RP-E, PC, and APC. This product is to be used in in situ hybridization techniques or other methods where fluorescence staining of DNA is required. PI excites at 535 nm, emits at 615 nm, producing a red fluorescence. RNA is also stained with PI.
Instructions for use
- Bring the vial to room temperature.
- Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light.
- Turn the vial upside down and remove any air bubbles.
- Apply 3-4 drops directly of mounting medium on top of the specimen and spread out evenly by tilting the slide back and forth or spread evenly with a 0.2 ml plastic pipette tip, making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide on paper towel.
- Let stand at room temperature for about 5 minutes.
- Apply cover slip, carefully avoiding air bubbles.
- The specimen is ready for visualization under microscope.
- One can seal the edges of cover slip with nail polish or any organic medium or our Limonene mounting medium (cat. E17987-01). If coverslip is not sealed air bubbles will appear in few days.
- For long term storage it is recommended that the slide be stored in the dark at 2-8°C.
Handling and storage
2-8°C, Protect from light, DO NOT FREEZE.
Removal of coverslip
Coverslip can be removed before sealing the edges. Soak slide in warm (37°C) distilled or deionized water for several minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.
More Information
Precautionary statements |
P403_233
P501
|
---|---|
Packing Unit | 20ml, 100ml |
ready to use | yes |
Storage Temperature | 2-8°C, protect from light, do not freeze |
suitable dyes | FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluoro 488, Alexa Fluoro 594, GFP, Tetramethylrhodamine, Redox, RP-E, PC, APC |
Suitable for | Immunofluorescence, confocal microscopy |
Used for Fluorescence |
yes
|
SDS (multilingual) | E17985-60/-61 |