+49 (089) 18 93 668 0 - Info@ScienceServices.de   We are here for you! Call us or request a call back here.
Language

EMS Shield Mount

EMS Shield Mount is an aqueous non-permanent, low viscosity mounting medium for immunofluorescence. Suitable for FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, GFP, Tetramethylrhodamine, Redox.
Grouped product items
Product Name Qty
EMS Shield, 30ml

E17985-09

€180.30 €214.56
EMS Shield, 100ml

E17985-100

€418.40 €497.90

Product Details

Description

EMS Shield Mount is an aqueous non-permanent, low viscosity mounting medium for immunofluorescence. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), Tetramethylrhodamine and Redox. The fluorescence is retained during storage at 4°C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of Cy dyes.

Instructions for use

  1. Bring the vial to room temperature.
  2. Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface.
  3. Turn the vial upside down and open the dropper to remove any air bubbles. Apply 2-3 drops of mounting medium and apply coverslip carefully without getting air bubbles.
  4. The specimen is ready for visualization under a microscope.
  5. The coverslip may move, so it may be necessary to seal the edges of cover slip with nail polish, any organic medium a Limonene mounting medium (E17987-01).
  6. Store slide at 2-8°C in the dark.


Handling and storage
2-8°C is recommended. Protect from light, DO NOT FREEZE.

Removal of coverslip
Coverslip can be removed before sealing the edges. Soak slide in warm (37°C) distilled or deionized water for several minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

More Information

More Information
Signal word
Warning
Symbol GHS
GHS07 GHS07
Hazard statements
H302_H312
H302_H312_H332
H315
Precautionary statements
P261
P280
P321
P301_312
P332_313
P420
P403_233
P501
Packing Unit 30ml, 100ml
ready to use yes
Storage Temperature 2-8°C
suitable dyes FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, GFP, Tetramethylrhodamine, Redox
Suitable for Immunofluorescence, confocal microscopy
Used for Fluorescence
yes
SDS (multilingual) E17985-09, E17985-100