+49 (089) 18 93 668 0 - Info@ScienceServices.de   We are here for you! Call us or request a call back here.
Language

EMS Glycerol Mount with PPD

EMS Glycerol Fluorescence Mount with strong anti-fading agent PPD (1,4-phenylenediamine), an aqueous mounting medium for fluorescencent tissues and cell smears. Suitable for FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Tetramethylrhodamine, Redox.
Grouped product items
Product Name Qty
EMS Glycerol with PPD, 20ml

E17989-70

€195.00 €232.05
EMS Glycerol with PPD, 100ml

E17989-71

€494.20 €588.10

Product Details

Description

EMS Glycerol Mount with strong anti-fading agent PPD (1,4-phenylenediamine) is an aqueous mounting medium for preserving fluorescence of tissues and cell smears. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Tetramethylrhodamine and Redox. The fluorescence is retained during prolonged storage at 4°C in the dark. This medium contains phenylenediamine and is not suitable for immunofluorescence of Cy dyes, Phycoerythrin (R-PE), Phyocyanin (PC) and Allophycocyanin (APC). This Reagent is a ready to use mounting medium with dark coffee color. This color does not interfere with Immunofluorescence.

Instruction for use
Dehydration of specimen is not required.

  1. Bring the vial to room temperature.
  2. Rinse slide to be mounted with distilled or deionized water; touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light.
  3. Turn the vial upside down and open the dropper to remove any air bubbles.
  4. Apply 2-3 drops of mounting medium directly on top of the specimen.
  5. Let stand at room temperature for about 3-5 minutes in the dark.
  6. Apply cover slip carefully avoiding air bubbles.
  7. The specimen is ready for visualization under a microscope.
  8. One can seal the edges of cover slip with nail polish or any organic medium. If a coverslip is not sealed air bubbles will appear in few days.
  9. Method for applying Coverslip: Put 1-2 drops of Mounting medium on the specimen. After 3-4 minutes apply coverslip carefully avoiding air bubbles. Put Kimwipes on the top of coverslip, press gently to remove excess mounting medium. With 200 micropipette add organic mounting medium to seal the edges.
  10. For storage it is recommended that the slide be stored in the dark at 2-8°C.

 

More Information

More Information
Packing Unit 20ml, 100ml
ready to use yes
Refractive Index 1.4563
Storage Temperature 2-8°C, protect from light, do not freeze
suitable dyes FITC, Texas Red, AMCA, Alexa fluoro 488, Alexa fluoro 594, Tetramethylrhodamine, Redox
Suitable for Immunofluorescence, confocal microscopy
Used for Fluorescence
yes