+49 (089) 18 93 668 0 - Info@ScienceServices.de   We are here for you! Call us or request a call back here.
Language

EMS Glycerol Mount with DAPI and DABCO™

EMS Glycerol with DAPI (4,6-Diamidino-2-phenylindol) and DABCO™ (1,4-Diazobicyclo-[2,2,2-octane]), an aqueous mounting medium for fluorescencent tissue and cell smears. Suitable for FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, GFP, Tetramethylrhodamine, Redox.
Grouped product items
Product Name Qty
EMS Glycerol with DAPI and DABCO™, 20ml

E17989-60

€235.90 €280.72
EMS Glycerol with DAPI and DABCO™, 100ml

E17989-61

€683.00 €812.77

Product Details

Description

EMS Glycerol with DAPI (4,6-Diamidino-2-phenylindol) and DABCO™ (1,4-Diazobicyclo-[2,2,2-octane]) is an aqueous mounting medium for preserving fluorescence of tissues and cell smears. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), Tetramethylrhodamine, Redox. Fluorescence is retained during prolonged storage at 4°C in the dark. This mounting medium is fortified with DAPI which is a counter-stain for DNA. This product is to be used in situ hybridization techniques or other methods where fluorescence of DNA staining is required. DAPI excites at 360nm and emits at 460nm, producing a blue fluorescence. RNA is also stained with DAPI. Not recommended for Phycoeythrin (PE), Phycocyanin (PC) and Allophycocyanin (APC).


Instruction for use
Dehydration of specimen is not required.

  1. Bring the vial to room temperature.
  2. Turn the vial upside down and open the dropper to remove any air bubbles.
  3. Apply 1-2 drops of mounting medium directly; cover slip carefully avoiding air bubbles.
  4. The specimen is ready for visualization under a microscope.
  5. One can seal the edges of cover slip with nail polish or any organic medium.
  6. Method for applying Coverslip: Put 1-2 drops of Mounting medium on the specimen. After 3-4 minutes apply coverslip carefully avoiding air bubbles. Put Kimwipes on the top of coverslip, press gently to remove excess mounting medium. With 200 micropipette add organic mounting medium to seal the edges.
  7. For storage it is recommended that the slide be stored in the dark at 2-8°C.

More Information

More Information
Signal word
Danger
Symbol GHS
GHS05 GHS05
Hazard statements
H314
Precautionary statements
P310
P321
P303_361_353
P305_351_338
P405
P501
Packing Unit 20ml, 100ml
ready to use yes
Refractive Index 1.4617
Storage Temperature 2-8°C, protect from light
suitable dyes FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, GFP, Tetramethylrhodamine, Redox
Suitable for Immunofluorescence, confocal microscopy
Used for Fluorescence
yes
SDS (multilingual) E17989-60/-61